MICROWAVE
COMPONENTS

|
Isolator
Module
|
|
|
|
|
|
input/output
Flange
|
|
CPR 340
|
CPR 430
|
CPR 430
|
|
Power
Rating
|
Watts
Continuous
|
6,500
|
10,000
|
15,000
|
|
Cooling
|
Water
|
Ã
|
Ã
|
Ã
|
|
Isolation
|
dB
Minimum
|
20
|
26
|
26
|
|
Insertion
Loss
|
dB
Maximum
|
.3
|
.1
|
.1
|
|
Actual
Weight
|
Pounds
/ kg
|
11 / 5
|
45 /
20.5
|
45 /
20.5
|
|
Reflected
Power Monitor
|
Detector
Diode
|
Ã
|
Ã
|
Ã
|
|
Stub
Tuner
|
|
|
|
|
|
input/output
Flange
|
Type
flange
|
CPR 340
|
CPR 430
|
CPR 430
|
|
Waveguide
Type
|
|
WR340
|
WR430
|
WR430
|
|
Power
Rating
|
Continuous
Watts
|
6,000
|
10,000
|
15,000
|
|
Tuning
Stubs
|
Number
preload & lock
|
2
|
3 *
|
3 *
|
|
Safety Interlocks
|
Switches on Flanges
|
Ã
|
Ã
|
Ã
|
|
Material
|
Allodyne
coated Aluminum
|
Ã
|
Ã
|
Ã
|
|
Actual Weight
|
Pounds / kg
|
4 / 1.8
|
20 / 9
|
20 / 9
|
|
Cooling
|
Water
|
no
|
Ã
|
Ã
|
|
Bandwidth
|
2.45
GHz +/- 50 MHz
|
Ã
|
Ã
|
Ã
|

Manual Tuners
|
Model
|
Power
|
.
|
Order #
|
|
MST3-284-3
|
3000
|
12-050000-50
|
|
MST3-284-3P
|
3000
|
12-050000-51
|
|
MST3-340-3
|
3000
|
12-050000-05
|
|
MST3-340-3P
|
3000
|
12-050000-06
|
|
MST3-340-6
|
6000
|
12-050000-25
|
|
MST3-340-6M
|
6000
|
12-050000-26
|
|
MST2-340-6C
|
6000
|
12-002000-13
|
Isolators
|
Model
|
Output Power (Watts)
|
Order #
|
|
ISO-340-1.2
|
1200
|
12-002000-30
|
|
ISO-284-2
|
2000
|
12-050000-52
|
|
ISO-340-6
|
6000
|
12-002000-27
|
Water Loads
|
Model
|
Output Power (Watts)
|
Order #
|
|
WL-284-3
|
3000
|
12-300001-34
|
|
WL-340-6
|
6000
|
12-300001-34
|
Directional Couplers
|
Model
|
Output Power (Watts)
|
Order #
|
|
DLC-284-60
|
Dual Loop Coupler
|
12-050000-54
|
|
DLC-340-60
|
Dual Loop Coupler
|
12-050003-00
|
|
DLC-430-60
|
Dual Loop Coupler
|
12-050000-55
|
|
LC-284-60
|
Loop Coupler
|
12-050003-25
|
|
LC-340-60
|
Loop Coupler
|
12-050000-56
|
|
LC-430-60
|
Loop Coupler
|
12-050000-57
|
|
DI-N-BNC Detector Diode
|
.
|
12-050003-07
|
Wave-Guide Sections
|
Model
|
Order #
|
|
WGT-340-100 Wave-guide
Transition
|
12-050001-09
|
|
WTG-340-100S Wave-guide
Transition w/Short
|
12-050001-00
|
|
WTG-284-340 Wave-guide
Transition
|
12-050000-58
|
|
CGT-284-7
Coax-WG Transition
|
12-050001-01
|
|
CGT-340-7 Coax-WG Transition
|
12-050001-00
|
|
EB-340 E-Bend
|
12-050002-00
|
|
HB-340 H-Bend
|
12-050000-58
|
|
SS-340 Sliding Short
|
12-050003-11
|
|
SS-340P Sliding Short
|
12-050003-10
|
Wave-Guide and
Accessories
|
Model
|
Order #
|
|
Wave-guide Sections w/ Flanges —
Custom
|
Consult Factory
|
|
Survey Meter
|
12-070002-00
|
|
WR284 Flange
|
12-050000-59
|
|
WR340 Flange
|
12-050000-60
|
|
WR430 Flange
|
12-050000-61
|
Request
Literature
Home | Company
| News | Contact | Download
RF Plasma Sources | RF
Plasma Power Supplies
DC Plasma Power Supplies | Microwave
Generators & Components
Manitou
Systems Inc.
18 Commerce Road,
Newtown, CT. 06470
Tel.203.270.8797 Fax.203.270.8786
This
website has been revised as of 03.25.07
Any
technical specification described on this website is subject to change without
prior notice.
Thank
you for visiting the Manitou Systems, Inc. website. Our privacy policy is
simple: we collect no personal information
about you unless you choose to provide that information to us. We do not give,
share, sell or transfer any
personal information to a third party.
All
Rights Reserved 2007, Manitou Systems, Inc. 18
Commerce Road, Newtown, CT. 06470
|
|